Where not subject to.
Pvc coated mc cable uses permitted.
12 gauge 2 conductor mc parking deck cable is ideal for use in branch circuit and feeder wiring for lighting control and signal circuits in wet dirty or oily locations buried directly in earth or concrete surface mounted or trenched for use in parking deck or parking lot applications golf courses ski mountains docks marinas pumping stations and stadium.
Products ordering resources about us.
The uses permitted for mc cable are governed by nec article 330 and any applicable local codes.
If installed in a wet location the metallic cover must be impervious to moisture or the insulated conductors must be listed for use in a wet location.
The most common is the pvc coated sunlight resistant direct burial listed mc cable in the image.
2 and class iii div.
2 exposed to the destructive corrosive conditions in a or b below unless the metallic sheath or armor is resistant to the conditions or protected by material resistant to the conditions.
Previous wording did not require the corrosion resistant jacket as a prerequisite to use the 3 conditions.
Sustainability careers contact us legal disclaimer.
Southwire patents southwire canada california supply chain act recalls.
Afc also offers parking deck lot cable pvc jacketed mc cable which is mc cable with galvanized steel armor with a pvc jacket.
The revised 2014 code language makes it clear that a corrosion resistant jacket must be present over the cable and then the 3 conditions apply.
Direct burial in the earth or embedded in concrete.
Please enter a valid email address.
Please refer to nec article 330 and your local authority having jurisdiction for additional information.
Armorlite type mc pvc jacketed neutral per phase cable view pdf.
Also used in continuous runs to outdoor or underground swimming pool motors pumps and related equipment per nec 680 fished exposed or concealed cable trays direct sunlight and hazardous locations up to class i ii div.
Section 330 10 a 13 covering the permitted uses of type mc cable contains a major change for the 2002 nec.
This cable is great for signal circuits in wet dirty or oily locations can be buried directly in earth or concrete surface mounted or trenched for use in parking deck or parking lot applications golf courses docks.
330 12 1 subject to physical damage.
1 2 nec articles 501 502 503 530 galvanized steel armor with pvc jacket.
Email has been submitted successfully.
Type mc cable with a nonmetallic jacket can also be used in a wet location.
Jacketed metal clad cable and teck cable metal clad cable type mc ref.